The devices belonging to the series EVK 700 are single or two outputs configurable digital timers able to work in a range betwe-
en 0.1 seconds and 99 hours and 59 minutes.You can set single output models to work in 4 different working modes and two outputs models in 9 different working modes; in order to make easier the configuration, the instrument will auto-
matically show/hide the configuration parameters according to the instrument code selected.
EVK 721/722 models also have the RTC function that will allow the user to plan the cycle activations.
You can set event causing commands start and stop (keyboard or low voltage digital input).
Thanks to the end-cycle buzzer, the bi-color display and the bac- klit icons, the user will be able to control the counting status and
its proper execution.
technical data
Box: self-extinguishing, grey.
Frontal protection: IP65.
Power supply: 230 VAC, 115 VAC, 12-24 VAC/DC, 12 VAC/DC; 50/60 Hz.
Alarm buzzer: included.
Digital inputs: two (remote start and stop).
Working range from -0.1s to 99h and 59min.
Relay outputs: load 1 (8 A res.@ 250 VAC relay).
load 2 (8 A res.@ 250 VAC relay), EVK 702/712/722 models only.
en 0.1 seconds and 99 hours and 59 minutes.You can set single output models to work in 4 different working modes and two outputs models in 9 different working modes; in order to make easier the configuration, the instrument will auto-
matically show/hide the configuration parameters according to the instrument code selected.
EVK 721/722 models also have the RTC function that will allow the user to plan the cycle activations.
You can set event causing commands start and stop (keyboard or low voltage digital input).
Thanks to the end-cycle buzzer, the bi-color display and the bac- klit icons, the user will be able to control the counting status and
its proper execution.
technical data
Box: self-extinguishing, grey.
Frontal protection: IP65.
Power supply: 230 VAC, 115 VAC, 12-24 VAC/DC, 12 VAC/DC; 50/60 Hz.
Alarm buzzer: included.
Digital inputs: two (remote start and stop).
Working range from -0.1s to 99h and 59min.
Relay outputs: load 1 (8 A res.@ 250 VAC relay).
load 2 (8 A res.@ 250 VAC relay), EVK 702/712/722 models only.